If you see an interesting thing in one of the windows on the RHIC X-term and you want to preserve it in the LOGBOOK, you need to do the following:
(standard plots listed on menu before first separator)
This page displays the 16 scaler channels (1 line for each scaler) sent to RHIC from Phobos.
This page gives control and status of voltage on the zero degree calorimeters.
For more details, goto ZCAL HV(pet) page on RHIC X-term
This page gives read only access to the PHOBOS magnet power supply. No password is required to start.
For more details, go to Magnet documentation
This plot shows the ring main dipole buss magnet currents as a function of time. Ensure autoscale is on, so see full range on display (goto setting menu)
This plot shows the number of ions in each ring as a function of time.
The vertical lines mark the beginning of the ramping period and when the beams go through
transition and other ramp "step-stones".
This page is a GPM (General Purpose Monitor) page that displays the ZDC coincidence rates reported to RHIC by the 4 experiments.
This page is a GPM (General Purpose Monitor) page that displays selected RHIC scalers of our paddle triggers
This displays the background at Phobos in various detectors. A value of about 100 in the Paddles and much less in the other detectors is normal.
This page displays the vacuum pressure (Torr) in our beam pipe. About 5X10^-10 is normal. Excursions up to a few times 10^-8 or more occur at the beginning of some stores. This is (presumably) the outgassing caused by the multi-packing electrons.
Other menu items to be documented.
This page shows the parameters of the RHIC crossing clock (delays) + bunch fill patterns as configured for Phobos.
For more details goto Beam Synch page on RHIC X-term
The event link page gives us access to the module, which we program, that interprets a CODE from RHIC (i.e. now running stabely code, about to use scrappers code) and outputs a logic pulse that we can use to turn on/off our system. (This module allows us to get info from RHIC selectively)
This page controls the PHOBOS magnet power supply.
For more details, go to Magnet documentation
Check that no duplicate processes are running on the RHIC x-term as shown by identical icons (.e.g. HV).
Check that displays of RHIC beam, magnets and scalers are updating. If not, close window and restart from menu. If trouble persists, call MCR and they will consult, as necessary, with Controls support.
This should be done by the operations manager only.