Re: T3 problems, was:RE: Shift report 20011005 16:00-24:00

From: Pawel Staszel (staszel@alf.nbi.dk)
Date: Fri Oct 05 2001 - 04:28:41 EDT

  • Next message: Flemming Videbaek: "re T3 and current running"

    Hi,
    If the T3 problem is cause by the large particles flux than we
    should observe a significant increase of the T3 anode currents.
    
    But, maybe during the T4 and T5 scan runs, by a mistake, the threshold was
    lowered on T3?
    
    Pawel.
    
    
    Ian Bearden wrote:
    
    > If BFS is at 3 and FFS is at 12 degrees, the reason T3 is not working might
    > be that it is drowning in particles.  In T1 we have something like 6-7 local
    > tracks, when T1 sits behind a magnet (which is on, and sweeps many particles
    > away!).  Perhaps T3 should be turned off when it is not shielded by the FFS.
    > Ian
    >
    > > -----Original Message-----
    > > From: owner-brahms-l@bnl.gov [mailto:owner-brahms-l@bnl.gov]On Behalf Of
    > > Apache
    > > Sent: Friday, October 05, 2001 6:12 AM
    > > To: brahms-l@bnl.gov; olchansk@bnl.gov; videbaek@bnl.gov
    > > Subject: Shift report 20011005 16:00-24:00
    > >
    > >
    > >
    > > ------------------------------------------------------------
    > > Date: Fri Oct  5 00:12:18 2001, Shift: 16:00-24:00
    > > Supervisor: hiro, with:
    > > Log book#9 pages 91 - 93
    > >
    > > Shift Summary:
    > > ------------------------------------------------------------
    > > 1.  beam for most of the shift
    > > It looks there is more Ions
    > > 2.  T5 scan run
    > >    run 5136 T5 Anode default
    > >    run 5137 T5 Anode +20V from default
    > >    run 5138 T5 Anode +40V from default
    > >    run 5139 T5 Anode -20V from default
    > >    run 5140 T5 Anode default, threshold=3.2V
    > >    run 5141 T5 Anode default, threshold=2.9V
    > >
    > >     T4 scan run
    > >    run 5142 T4 Anode default
    > >    run 5143 T4 Anode +20V from default
    > >    run 5144 T4 Anode +40V from default
    > >    run 5146 T4 Anode -20V from default
    > >    run 5147 T4 Anode default, threshold=3.0V
    > >    run 5148 T4 Anode default, threshold=2.7V
    > >
    > > People who are looking for DCs should look these run.
    > >
    > > To study background.
    > > Data run: 5150
    > > FFS at 12 deg at 1/5 field
    > > BFS at 3 deg at 1/5 field
    > > MRS at 60 deg at 700A
    > >
    > >
    > > 3.  DAQ, T3-map errors.  Here is the error in DAQ.
    > > (
    > > T3-map error
    > > non-fatal unpakcing errors
    > > fatal unpakcing erros, fatal
    > > truncated fastbus data: current limit (set my readout list ) is 8000
    > > )
    > >
    > > T3 does not seem to be working.
    > >
    > >
    > > ------------------------------------------------------------
    > >
    > >
    
    --
     ----------------------------------------------------------------------
    | Pawel Staszel                                                        |
    | Niels Bohr Institute Tb 8    email:      staszel@nbi.dk              |
    | Blegdamsvej 17               phone:      (+45) 35 32 53 51           |
    | København Ø                    FAX:      (+45) 35 32 50 16           |
    | Danmark                                                              |
     ----------------------------------------------------------------------
    



    This archive was generated by hypermail 2b30 : Fri Oct 05 2001 - 04:29:22 EDT