A new version of BRAHVO (BRAHMS High VOltage control system) has now been committed to the CVS and installed on the operators account. I should now be possible control all types of detectors and mainframes (which means that it's not necessary to use the vt100-like control programs for the L1458A and L1458B mainframes). Here is a few comments on how it looks. Included detectors: H1, C1, H2, TOFW, BBR, BBL, TILES, Si, T1, T2, MTPC1, MTPC2, T3. Channel Mapping: Information on channel mapping has been found in the shift report, and I'm not 100% confident that it's correct (the shift report is not consistent). If you want to be sure that the channel mapping is correct for a given detector, please check the setting file in the /opus/home/operator/HV/config/. New stuff: Control window for the TPC's, the Si and T3. If you press the Label button (to the left) for a channel a control window will appear, here you can change voltage, ramp speed, trip limit, etc. You can also enable/disable a channel by pressing the check button next to the label button (this feature is only available for channel connected to a Lecroy 1458 mainframe) - this corresponds to the ] and the [ commands on the old L1458 control windows. Users manual: Is on its way. Please don't hesitate to contact me if you have any questions, comments or suggestion. Thanks, Claus Ekman Jorgensen Phone : (+45) 33 32 49 49 Office : (+45) 35 32 53 05 E-mail : ekman@nbi.dk
This archive was generated by hypermail 2b29 : Tue Aug 29 2000 - 16:54:22 EDT