| Date: | __________________ |
| Time: | __________________ |
| Person: | __________________ |
<% if shifttype=1 Then %>
| Instructions | Measurements | Actions to Take | Comments |
| Temperature in Electronics Room | _______C | If >29C page/call Robert | |
| Check all heaters off | YES NO | Turn knob counter-clockwise to low | |
| Check if "Detector Status" = (old) (Si Hybrids may be old if DAQ with Si is not running) |
System=_____ ___________ |
If (old) database is not updating. Check monitor for that particular system, attempt restart if necessary, and notify system expert. If DAQ is running and Silicon is ON and Si Hybrids is (old) call DAQ expert or Si expert. |
| Instructions | Measurements | Actions To Take | Comments |
| Check Temperature and Humidity in Tunnel including history (click on number) |
~______C ~______% |
If >24C and Humdity>60% ensure ODH fans off. If ODH Fans
on
call MCR. If still no resolution call Robert. If rapid variations in temp or humidity follow above proceedure. |
|
| Check Temperature and Humidity in Enclosure including history (click on number) |
~______C ~______% |
If >24C and Humdity>60% ensure ODH fans off. If ODH Fans
on
call MCR. If still no resolution call Robert. If rapid variations in temp or humidity follow above proceedure. |
1. FEC Power Supplies |
||||
1.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If they do not agree , write in logbook, call Si expert.If all FEC Power Supplies are off, jump to section 2. | |
1.2 |
If there are FEC Power Supplies ON: | |||
| - Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, go to next step. If yes, jump to section 2. | |||
| - Do the NOT OK red indicators correspond to voltages? | ||||
| Yes c No c | If yes, go to manual for appropriate action. | |||
| - Do the NOT OK red indicators correspond to fans? | ||||
| Yes c No c | If yes, go to manual for appropriate action. | |||
| - Do the NOT OK red indicators correspond to currents? | ||||
| Yes c No c | Check the history graph. If the current is increasing very rapidly, call expert. Otherwise, make note in logbook. | |||
2. Bias Power Supplies |
||||
2.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If not, write in logbook, call Si expert. If yes, jump to 3. | |
2.2 |
If there are Bias Power Supplies ON: | |||
| -Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, write in logbook, call Si expert. | |||
3. Cooling System |
||||
3.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If not, write in logbook, call Si expert or Robert. If yes, jump to 4. | |
3.2 |
If the Cooling System is ON: | |||
| -Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, go to next step. If yes, jump to 4. | |||
| - Is there any red flow indicator on any of the subsystems? | ||||
| Yes c No c | Write in the logbook which indicator is red. | |||
| - Are there any other red indicators? | ||||
| Yes c No c | If yes, report in logbook, call Robert. If not, go to 4. | |||
4. UPSs |
|
4.1 |
On the Portal, click on UPS, under "Detector Status" Check that "Output Status" is Online, and "Battery Capacity" is ~100%. |
| High Voltage To TOF | Look at HV_Control.vi on the Plastic computer. | ||
| Nominal TOF Status | Actual TOF Status | Agree? | |
| On c Off c | On c Off c | Yes c No c |
If they disagree, inform TOF expert |
| Instructions | Measurements | Comments | Actions To Take |
| TOF Discriminators | |||
| Go to the Camac controls VI. | Is X and Q valid? | Yes c No c |
If no, read out crates and recheck. If still invalid, note in logbook and restart. |
| In Tunnel Checks | |||
| Go to the TOF UPS's. | TOF UPS's On? | Yes c No c |
If No, Call TOF expert. |
| Look at the TOF Camac crates. | Are the crates on? | Yes c No c |
If No, Call TOF expert. |
| Are discriminators set to remote mode? (Indicated by a red LED on module.) | Yes c No c |
If No, note in logbook. | |
| Diagnostic Run Mode Checks | |||
| Go to the 4-fold logic unit in the TOF NIM bin. Look at the UPPER unit only. | Are channels A,B,C and D Off? (Upper part.) | Yes c No c |
If no, insert pin into pinholes A, B, C, and D if one isn't present. |
| Go to the LED HV is located above the HV mainframe. | Is LED HV Off? | Yes c No c |
If No, dail down, counter clock wise, the HV to zero and disable HV. |
| Look at the Time Calibrator in the TOF NIM Bin. | Is Time Calibrator Off? | Yes c No c |
If No, switch off. |
| In Tunnel Checks | |||
| The Trigger Racks are those close to the Paddle counters. | Camac, Nim bins and fans on? (It's alright if the fans on the bottom NIM bins are off) |
Yes c No c | If No, contact local trigger expert |
| Check camac crate voltages are the voltages within range (-+ .3V) ? | Yes c No c | If No, contact local
trigger expert
|
| High Voltage To TRIGGER counters | Look at HV_Control.vi on the Plastic computer. | |||
| Nominal State | Actual State | Agree? | Actions to Take | Comments |
| On c Off c | On c Off c | Yes c No c | If they disagree, contact local trigger expert | |
| High Voltage to ZDC | In ZDC HV (pet) window on RHIC X-term. | |||
| Nominal State | Actual State | Agree? | Actions To Take | Comments |
| On c Off c | On c Off c | Yes c No c | If they disagree, contact local trigger expert | |
| Nominal and measured voltages agree within 50 volts | Yes c No c | If they disagree, contact local trigger expert | ||
| Trigger Discriminator | Compare image of Camac_Control.vi with nominal state image (under documentation->trigger) | ||
| Do the nominal and actual states agree? | Actions to Take | Comments | |
| Positive | Yes c No c | If they disagree, contact local trigger expert | |
| Negative | Yes c No c | If they disagree, contact local trigger expert | |
| Electronics Room Check | The Trigger Rack is directly in front of the electronics door. | ||
| Instructions | Actual state | Action to Take | Comments |
| Red switches of Fans A, B, C, D | On c Off c
|
If Off contact local trigger expert. | |
| Nim bins LED's A ,B , C, D | On c Off c | If Off contact local trigger expert. | |
| Instructions | Measurements | Comments | Actions To Take | ||||
| 1.) Click on "Beam Loss Monitors" on portal. Then click on Spikes last 48 hrs. Have there been any spikes in the last 8 hours that have not already been noted in the logbook? |
|
Yes: Call MCR to see what was being done during that
time and write note in logbook. Then continue to 2.)
No: Continue to 2.) |
|||||
| 2.) In "Beam Loss Monitor" page, click on each value in 'Dose' column to view history for that monitor. | Check for spuriously high doses 3.6 rad/hr above the base level not already noted in logbook in BLMs (ignore spuriously low values) and in chipmunks. Read documentation for description of base level. | Yes: Call MCR to find out if they were doing anything
during that time and write note in logbook. Then continue to 3.)
No: continue to 3.) |
|||||
| 3.) Check the nominal status for the radiation monitoring. Does the BLM entry say ON? |
|
Yes: Proceed to step 4.) No: You are done with the check for this subsytem. |
|||||
| 4.) Is the Radiation Monitoring Program even open (both BLM and Chipmunks)? |
|
Yes: go onto 5.) No: Double click the icon on the desktop labeled BLMmonitor for the BLM display and Chipmunkmonitor for the Chipmunk display. Click the white arrow in the upper left to run the program and go on to 5.) |
|||||
| 5.) Are the charts in the front scrolling (slowly) and do the instant doses and the timestamp on the BLM display appear to be updating? |
|
Yes: You are done with the check for this subsystem. No: Proceed to 6.) in the radiation monitoring documentation. |
Currently nothing to check
Nothing to check for this subsystem
| Instructions | Measurements | Comments | Actions To Take |
| Instructions | Measurements | Actions To Take | Comments |
| Check "No runs have problems with data tracking" window on phucsia | Green Red/Yellow | If Green continue to next line
If Red/Yellow follow instructions on DV page "Checklist instructions" |
|
| Check "Runs to be validated" window on phucsia | Green Red/Yellow | If Green continue checklist
If Red/Yellow follow instructions on DV page "Checklist instructions" |
Currently nothing to check
<% Elseif shifttype=2 Then %>| Instructions | Measurements | Actions to Take | Comments |
| Temperature in Electronics Room | _______C | If >29C page/call Robert | |
| Check all heaters off | YES NO | Turn knob counter-clockwise to low | |
| Check if "Detector Status" = (old) (Si Hybrids may be old if DAQ with Si is not running) |
System=_____ ___________ |
If (old) database is not updating. Check monitor for that particular system, attempt restart if necessary, and notify system expert. If DAQ is running and Silicon is ON and Si Hybrids is (old) call DAQ expert or Si expert. |
| Instructions | Measurements | Actions To Take | Comments |
| Check Temperature and Humidity in Tunnel including history (click on number) |
~______C ~______% |
If >24C and Humdity>60% ensure ODH fans off. If ODH Fans
on
call MCR. If still no resolution call Robert. If rapid variations in temp or humidity follow above proceedure. |
|
| Check Temperature and Humidity in Enclosure including history (click on number) |
~______C ~______% |
If >24C and Humdity>60% ensure ODH fans off. If ODH Fans
on
call MCR. If still no resolution call Robert. If rapid variations in temp or humidity follow above proceedure. |
1. FEC Power Supplies |
||||
1.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If they do not agree , write in logbook, call Si expert.If all FEC Power Supplies are off, jump to section 2. | |
1.2 |
If there are FEC Power Supplies ON: | |||
| - Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, go to next step. If yes, jump to section 2. | |||
| - Do the NOT OK red indicators correspond to voltages? | ||||
| Yes c No c | If yes, go to manual for appropriate action. | |||
| - Do the NOT OK red indicators correspond to fans? | ||||
| Yes c No c | If yes, go to manual for appropriate action. | |||
| - Do the NOT OK red indicators correspond to currents? | ||||
| Yes c No c | Check the history graph. If the current is increasing very rapidly, call expert. Otherwise, make note in logbook. | |||
2. Bias Power Supplies |
||||
2.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If not, write in logbook, call Si expert. If yes, jump to 3. | |
2.2 |
If there are Bias Power Supplies ON: | |||
| -Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, write in logbook, call Si expert. | |||
3. Cooling System |
||||
3.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If not, write in logbook, call Si expert or Robert. If yes, jump to 4. | |
3.2 |
If the Cooling System is ON: | |||
| -Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, go to next step. If yes, jump to 4. | |||
| - Are there any red flow indicators on any of the subsystems? | ||||
| Yes c No c | Write in the logbook which indicator is red. | |||
| - Are there any other red indicators? | ||||
| Yes c No c | If yes, report in logbook, call Robert. If not, go to 4. | |||
4. UPSs |
|
4.1
|
On the Portal, click on UPS, under "Detector Status" Check that "Output Status" is Online, and "Battery Capacity" is ~100%. |
| High Voltage To TOF | Look at HV_Control.vi on the Plastic computer. | ||
| Nominal TOF Status | Actual TOF Status | Agree? | |
| On c Off c | On c Off c | Yes c No c |
If they disagree, inform TOF Expert. |
| Instructions | Measurements | Comments | Actions To Take |
| TOF Discriminators | |||
| Go to the Camac controls VI. | Is X and Q valid? | Yes c No c |
If no, read out crates and recheck. If still invalid, note in logbook and restart vi. |
| Diagnostic Run Mode Checks | |||
| Go to the 4-fold logic unit in the TOF NIM bin. Look at the UPPER unit only. | Are channels A,B,C and D Off? (Upper part.) | Yes c No c |
If no, insert pin into pinholes A, B, C, and D if one isn't present. |
| The LED HV is located above the HV mainframe. | Is LED HV Off? | Yes c No c |
If No, dail down, counter clock wise, the HV to zero and disable HV. |
| Look at the Time Calibrator in the TOF NIM Bin. | Is Time Calibrator Off? | Yes c No c |
If No, switch off. |
| High Voltage To TRIGGER counters | Look at HV_Control.vi on the Plastic computer. | |||
| Nominal State | Actual State | Agree? | Actions to Take | Comments |
| On c Off c | On c Off c | Yes c No c | If they disagree, contact local trigger expert | |
| High Voltage to ZDC | In ZDC HV (pet) window on RHIC X-term. | |||
| Nominal State | Actual State | Agree? | Actions To Take | Comments |
| On c Off c | On c Off c | Yes c No c | If they disagree, contact local trigger expert | |
| Nominal and measured voltages agree within 50 volts | Yes c No c | If they disagree, contact local trigger expert | ||
| Trigger Discriminator | Compare image of Camac_Control.vi with the nominal state (under documentation -> trigger) | ||
| Crate | Do the nominal and actual states agree? | Actions to Take | Comments |
| Positive | Yes c No c | If they disagree, contact local trigger expert | |
| Negative | Yes c No c | If they disagree, contact local trigger expert | |
| Electronics Room Check | The Trigger Rack is directly in front of the electronics door. | ||
| Instructions | Actual state | Action to Take | Comments |
| Red switches of Fans A, B, C, D | On c Off c
|
If Off contact local trigger expert. | |
| Nim bins LED's A ,B , C, D | On c Off c | If Off contact local trigger expert. | |
| Instructions | Measurements | Comments | Actions To Take | ||||
| 1.) Click on "Beam Loss Monitors" on portal. Then click on Spikes last 48 hrs. Have there been any spikes in the last 8 hours that have not already been noted in the logbook? |
|
Yes: Call MCR to see what was being done during that
time and write note in logbook. Then continue to 2.)
No: Continue to 2.) |
|||||
| 2.) In "Beam Loss Monitor" page, click on each value in 'Dose' column to view history for that monitor. | Check for spuriously high doses 3.6 rad/hr above the base level not already noted in logbook in BLMs (ignore spuriously low values) and in chipmunks. Read documentation for description of base level. | Yes: Call MCR to find out if they were doing anything
during that time and write note in logbook. Then continue to 3.)
No: continue to 3.) |
|||||
| 3.) Check the nominal status for the radiation monitoring. Does the BLM entry say ON? |
|
Yes: Proceed to step 4.) No: You are done with the check for this subsytem. |
|||||
| 4.) Is the Radiation Monitoring Program even open (both BLM and Chipmunks)? |
|
Yes: go onto 5.) No: Double click the icon on the desktop labeled BLMmonitor for the BLM display and Chipmunkmonitor for the Chipmunk display. Click the white arrow in the upper left to run the program and go on to 5.) |
|||||
| 5.) Are the charts in the front scrolling (slowly) and do the instant doses and the timestamp on the BLM display appear to be updating? |
|
Yes: You are done with the check for this subsystem. No: Proceed to 6.) in the radiation monitoring documentation. |
| Instructions | Measurements | Comments | Actions To Take |
| 1) Make sure DAQ is running. GUI should be visible on the DAQ x-term | YES ____ |
Yes: Continue checklist No: If there isn't a good reason for DAQ not running(development/commissioning), start up the GUI and DAQ using documentation. |
|
| 2) Check that Run Status button is Green. | YES ____ |
Yes: Make sure Event counter is increasing (updates every
5 seconds) and you are done with the check for this subsytem. Proceed to checking the
online systems are running getting data from DAQ. No: Continue checklist |
|
| Is the RUN status Red? | YES ____ NO______ |
DAQ was stopped | Yes:The DAQ should usually be running collecting data.
Red button indicates No Run in progress. Press STOP run a couple of times and Use the
documentation to start a new run of type determined by current beam/detector status. Nominally [RunType=PADDLECOSM, Silicon disabled] for trigger commissioning. [RunType= ALLBEAM, Silicon enabled] for normal data-taking. Refer to
documentation if you have problems. |
| If you pressed Start Run and got no response (most common mode of failure) | Yes:Refer to documentation to restart the GUI and try
starting a new run. Make sure RunSetup selections (Silicon enable/disable, Fastbus
enable/disable switches) are set properly, and be sure to wait between steps like stopping
and starting runs. Note in the Shift Logbook in as much detail as possible, the conditions under which the freeze occured, so expert can look at it. If problems persist, call Expert |
Nothing to check
Nothing to Validate
| Instructions | Measurements | Actions To Take | Comments |
| Check "No runs have problems with data tracking" window on phucsia | Green Red/Yellow | If Green continue to next line
If Red/Yellow follow instructions on DV "Checklist instructions page" |
|
| Check "Runs to be validated" window on phucsia | Green Red/Yellow | If Green continue checklist
If Red/Yellow follow instructions on DV "Checklist instructions page" |
Currently nothing to check
<% Elseif shifttype=3 Then %>| Instructions | Measurements | Actions to Take | Comments |
| Temperature in Electronics Room | _______C | If >29C page/call Robert | |
| Check all heaters off | YES NO | Turn knob counter-clockwise to low | |
| Check if "Detector Status" = (old) (Si Hybrids may be old if DAQ with Si is not running) |
System=_____ ___________ |
If (old) database is not updating. Check monitor for that particular system, attempt restart if necessary, and notify system expert. If DAQ is running and Silicon is ON and Si Hybrids is (old) call DAQ expert or Si expert. | |
| Instructions | Measurements | Actions To Take | Comments |
| Check Temperature and Humidity |
~______C ~______% |
If >24C and Humdity>60% ensure ODH fans off. If ODH Fans
on
call MCR. If still no resolution call Robert. If rapid variations in temp or humidity follow above proceedure. |
|
| Check Temperature and Humidity in Enclosure including history (click on number) |
~______C ~______% |
If >24C and Humdity>60% ensure ODH fans off. If ODH Fans
on
call MCR. If still no resolution call Robert. If rapid variations in temp or humidity follow above proceedure. |
1. FEC Power Supplies |
||||
1.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If they do not agree , write in logbook, call Si expert.If all FEC Power Supplies are off, jump to section 2. | |
1.2 |
If there are FEC Power Supplies ON: | |||
| - Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, go to next step. If yes, jump to section 2. | |||
| - Do the NOT OK red indicators correspond to voltages? | ||||
| Yes c No c | If yes, go to manual for appropriate action. | |||
| - Do the NOT OK red indicators correspond to fans? | ||||
| Yes c No c | If yes, go to manual for appropriate action. | |||
| - Do the NOT OK red indicators correspond to currents? | ||||
| Yes c No c | Check the history graph. If the current is increasing very rapidly, call expert. Otherwise, make note in logbook. | |||
2. Bias Power Supplies |
||||
2.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If not, write in logbook, call Si expert. If yes, jump to 3. | |
2.2 |
If there are Bias Power Supplies ON: | |||
| -Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, write in logbook, call Si expert. | |||
3. Cooling System |
||||
3.1 |
Nominal state | Actual State | Agree? | |
| On c Off c | On c Off c | Yes c No c | If not, write in logbook, call Si expert or Robert. If yes, jump to 4. | |
3.2 |
If the Cooling System is ON: | |||
| -Are all corresponding indicators in Si Monitor green? | ||||
| Yes c No c | If not, go to next step. If yes, jump to 4. | |||
| - Are there any red flow indicators on any of the subsystems? | ||||
| Yes c No c | Write in the logbook which indicator is red. | |||
| - Are there any other red indicators? | ||||
| Yes c No c | If yes, report in logbook, call Robert. If not, go to 4. | |||
4. UPSs |
|
4.1 |
On the Portal, click on UPS, under "Detector Status" Check that "Output Status" is Online, and "Battery Capacity" is ~100%. |
5. Alarms |
||
5.1 |
Is Alarms.vi running? |
|
| Yes c No c | If not, double-click the alarms.vi icon on the desktop. | |
5.2 |
Can you hear the alarm after pressing the test button? | |
| Yes c No c | If not, try adjusting the volume on the speakers. | |
| High Voltage To TOF | Look at HV_Control.vi on the Plastic computer. | ||
| Nominal TOF Status | Actual TOF Status | Agree? | |
| On c Off c | On c Off c | Yes c No c |
If they disagree, inform TOF expert |
| Instructions | Measurements | Comments | Actions To Take |
| TOF Discriminators | |||
| Go to the Camac controls VI. | Is X and Q valid? | Yes c No c |
If no, read out crates and recheck. If still invalid, note in logbook and restart. |
| Diagnostic Run Mode Checks | |||
| Go to the 4-fold logic unit in the TOF NIM bin. Look at the UPPER unit only. | Are channels A,B,C and D Off? (Upper part.) | Yes c No c |
If no, inform TOF expert. |
| The LED HV is located above the HV mainframe. | Is LED HV Off? | Yes c No c |
If No, inform TOF expert. |
| Look at the Time Calibrator in the TOF NIM Bin. | Is Time Calibrator Off? | Yes c No c |
If No , inform TOF expert. |
| High Voltage To TRIGGER counters | Look at HV_Control.vi on the Plastic computer. | |||
| Nominal State | Actual State | Agree? | Actions to Take | Comments |
| On c Off c | On c Off c | Yes c No c | If they disagree, contact local trigger expert | |
| High Voltage to ZDC | In ZDC HV (pet) window on RHIC X-term. | |||
| Nominal State | Actual State | Agree? | Actions To Take | Comments |
| On c Off c | On c Off c | Yes c No c | If they disagree, contac local trigger expert | |
| Nominal and measured voltages agree within 50 volts | Yes c No c | If they disagree, contact local trigger expert | ||
| Trigger Discriminator | Compare image of Camac_Control.vi
with nominal state under documentation -> trigger (click on the square green buttons on top of left-hand window to switch between the positive and negative displays) |
||
| Do the nominal and actual states agree? | Actions to Take | Comments | |
| Positive | Yes c No c | If they disagree, contact local trigger expert | |
| Negative | Yes c No c | If they disagree, contact local trigger expert | |
| Record the visual scalers in the chart
below. Do not stop the scalers to make the measurements (make estimates where
necessary). Do not reset the scalers. Scalers are reset only at 10 am. Each morning at 10 am, the shift crew should reset the scalers and record the reset time in the online logbook. Please write any comments you feel pertinent ('start of run', 'middle of long store', 'beams steered in our area', etc.) If you want to print this table without printing out the whole checklist, go here. |
||||||||||||
| Date: Time: Blue Beam Current ( /10^6 ions): Yellow Beam Currents (/10^6 ions): |
||||||||||||
|
||||||||||||
|
||||||||||||
|
||||||||||||
|
||||||||||||
|
||||||||||||
|
| Electronics Room Check | The Trigger Rack is directly in front of the electronics door. | ||
| Instructions | Actual state | Action to Take | Comments |
| Red switches of Fans A, B, C, D | On c Off c
|
If Off contact local trigger expert. | |
| Nim bins LED's A ,B , C, D | On c Off c | If Off contact local trigger expert. | |
| Instructions | Measurements | Comments | Actions To Take | ||||
| 1.) Click on "Beam Loss Monitors" on portal. Then click on Spikes last 48 hrs. Have there been any spikes in the last 8 hours that have not already been noted in the logbook? |
|
Yes: Call MCR to see what was being done during that
time and write note in logbook. Then continue to 2.)
No: Continue to 2.) |
|||||
| 2.) In "Beam Loss Monitor" page, click on each value in 'Dose' column to view history for that monitor. | Check for spuriously high doses 3.6 rad/hr above the base level not already noted in logbook in BLMs (ignore spuriously low values) and in chipmunks. Read documentation for description of base level. | Yes: Call MCR to find out if they were doing anything
during that time and write note in logbook. Then continue to 3.)
No: continue to 3.) |
|||||
| 3.) Check the nominal status for the radiation monitoring. Does the BLM entry say ON? |
|
Yes: Proceed to step 4.) No: You are done with the check for this subsytem. |
|||||
| 4.) Is the Radiation Monitoring Program even open (both BLM and Chipmunks)? |
|
Yes: go onto 5.) No: Double click the icon on the desktop labeled BLMmonitor for the BLM display and Chipmunkmonitor for the Chipmunk display. Click the white arrow in the upper left to run the program and go on to 5.) |
|||||
| 5.) Are the charts in the front scrolling (slowly) and do the instant doses and the timestamp on the BLM display appear to be updating? |
|
Yes: You are done with the check for this subsystem. No: Proceed to 6.) in the radiation monitoring documentation. |
| Instructions | State | Actions To Take |
| Check for flashing yellow lights on top of the Fastbus crate | flashing or constantly shining | Yes: You are done with the check for this subsytem No: Continue checklist |
| Check for Green Status button on the DAQ-GUI on DAQ xterm. | 'green' : OK 'red' : No Run |
Green: You are done with this subsystem. Red : Hit Stop Run a couple of times to clear subsystems and Start a new Run. |
Go to the RHIC X-term computer and find the 'Magnet' control window. Avoid starting a duplicate window.
| Instructions | Measurements | Actions To Take | Comments |
| Go to Magnet control window on RHIC X-term. Click on Diagnostics, then Check Readback Mode. A message with the present value will be added to the message log at bottom of window. | [Readback] Mode is
A c B c |
If Readback Mode is set to A, no further action is needed. If it is B a pop-up will ask whether it should be changed. If normal running, click Yes, if CAS is working on PS, click No. |
Go to the Magnet Monitoring Program on the 'MAGMON' computer.
| Instructions | Measurements | Actions To Take | Comments |
| Is there a black arrow in window 'MobitorMagnet.vi'? | Yes c No c | If NO, click on the 'arrow' to start the VI. Double click on the 'Magnet Monitoring' icon on the desktop if there is no 'MobitorMagnet.vi' window. | |
| Look at 'StatusStringM' in the window, does the string say 'Off'? | Magnet is
On c Stby c Off c |
If the magnet is 'Off' you can ignore 'Fault' or 'Component Fault' messages. |
| Instructions | Measurements | Actions To Take | Comments |
| RHIC X-term Regular check | |
| Check that display of PHOBOS RHIC scalers (Phobos Triggers
and Phobos Chipmunks) are updating.
Also check High Voltage (zcal) display. If red, no reports are being received. |
If they are not: First close the window and attempt to
restart from root menu. If display remains blank (or red):
Weekdays: call MCR and ask them to report to Controls Support that the PHOBOS FEC is down. Nights & weekends: Push white button and inform MCR that we have rebooted our RHIC FEC. If further trouble ask for Support call. |
<% End If %>