------------------------------------------------------------ Date: Thu Oct 18 15:57:36 2001, Shift: 08:00-16:00 Supervisor: bbudick, with: jcibor Log book#10 pages 27 - 29 Shift Summary: ------------------------------------------------------------ 1. Beam from 9:30 am until 1 pm. Main Magnet Supply Problem aborted rest of shift. 2. Run 5407, 223K trigger 1, completed data taking at 1/5 field. Run 5408, ~70K at 1/3 field 3. Run 5420 at this field had about 33K trigger1, but with DAQ lights T5-map and T3-map flashing. 4. RunError messages,IoServer crashes possibly linked to high current on T5 anode 1, 29 microamps. Lowered and raised T5 anode 1 voltage and were able to take data in run5420 with ~33 K trigger 1. Instabilities in anode and cathode currents in T5 possibly linked to fluctuations in beam background. Otherwise no detector problems. ------------------------------------------------------------
This archive was generated by hypermail 2b30 : Thu Oct 18 2001 - 15:58:15 EDT