------------------------------------------------------------ Date: Mon Sep 24 06:45:52 2001, Shift: 08:00-16:00 Supervisor: James Norris, with: Log book#9 pages 33 - 33 Shift Summary: ------------------------------------------------------------ 1. ~01:30 MCR called and wanted to dump beam due to low rates. They asked if I had an objection, and I said I was happy with aZDC rate of ~65, but they elected to dump beam. They promised we would have another beam before the 05:30 access time. They, well, uh, lied. Beam was not re-established due to a "F6 Septum fault". 2. Data run #4895 from 00:05-02:50 Pedestal run #4896 - pulser scaledown incorrect Pedestal run #4897 TPC Pedestal run #4898 LED test run #4899 3. Mainframes still misbehaving making BRAHVO reading/control of T3 & T5 unreliable. Shift leader unreliable - forgot twice to write down run end times, doesn't know where to find trigger counts, didn't run brntuple until after running pedestal runs and suspects this is why brntuple gave "no event -0" error, and managed to hang pii4. Maybe we should take him out back and beat the stuffing out of him. ------------------------------------------------------------
This archive was generated by hypermail 2b30 : Mon Sep 24 2001 - 06:46:16 EDT