Hi This is unusual, I have certainly not seen anything like that before. To check where stuff went bad, check the histograms in the gtr production (for Mrstracking and the refitting). In general the MRS.fP comes from the global track ie. refitting while the fD5.fP from the initial matching. Hopefully this helps. Please when you send out pleas for help indicate what runs, and dst versions,, your are looking at. Flemming -------------------------------------------- Flemming Videbaek Physics Department Bldg 510-D Brookhaven National Laboratory Upton, NY11973 phone: 631-344-4106 cell: 631-681-1596 fax: 631-344-1334 e-mail: videbaek @ bnl gov ----- Original Message ----- From: "Bekele, Selemon" <bekeleku_at_ku.edu> To: <brahms-dev-l_at_lists.bnl.gov> Sent: Thursday, January 04, 2007 7:05 PM Subject: [Brahms-dev-l] MRS momentum distribution > > Hi Brahms, > > I started looking into the MRS spectra. I ran into > a problem when trying to access the momentum distribution: > > MRS_fP gives 0 > MRS_fD5_fP gives both positive and negative values > > could this be a problem in the dst production? > > Please have a look at > > http://www4.rcf.bnl.gov/~tigist/MrsCheck/ > > > Thanks > > Selemon, > _______________________________________________ > Brahms-dev-l mailing list > Brahms-dev-l_at_lists.bnl.gov > http://lists.bnl.gov/mailman/listinfo/brahms-dev-l > _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l_at_lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Thu Jan 04 2007 - 23:31:57 EST
This archive was generated by hypermail 2.2.0 : Thu Jan 04 2007 - 23:32:22 EST