Re: [Brahms-dev-l] update to analyze_app, brat

From: Hironori Ito <hito@rcf.rhic.bnl.gov>
Date: Fri Nov 04 2005 - 17:34:10 EST
Are you suggesting that you could not reach AFS?   At what time?  From 
which machine?  I don't have any problem accessing a file in our afs 
(/opt/brahms/)  And, I did not get any message from RCF about AFS 
problem today.

Hiro

Bekele, Selemon wrote:

>Hi Flemming,
>
>
>   I checked out analyze_app from cvs and tried to do
>
>        ./autogen
>        ./configure
>
>and I got the error
>
>    checking for root-config... no
>    configure: error: ROOT config script not found!
>
>Something must have happened even earlier since I was not able to do
>
>      make
>      make install
>
>with  error messages like
>
>     /opt/brahms/pro/include/root: Connection timed out
>     make[1]: *** [ProgressMeter.lo] Error 1
>     make[1]: Leaving directory `/direct/brahms+u/tigist/MyBrahms/brahms_app/tml_app/analyze_app/util'
>     make: *** [all-recursive] Error 1
>
>Any ideas what I should do?
>
>Selemon,
>   
>
> 
>
>
>-----Original Message-----
>From: brahms-dev-l-bounces@lists.bnl.gov on behalf of Flemming Videbaek
>Sent: Fri 11/4/2005 1:24 PM
>To: devlist
>Subject: [Brahms-dev-l] update to analyze_app, brat
> 
>The analyze app has ben updated with modification to the acceptance code.
>The main point was to introduce new maps for xf-pt . It is quite similar to the pVsTheta maps already there.
>During implementing this several problems were identified.
>- The code did not run due to typo's in newly added options for fiducial cuts. (fixed)
>- The inputoptions for fidicuals cuts are set to -99 and 99 in most cases. This in fact means the code does  not check
>  that tracks are inside the physical volumens at all. Corrected to get the volume size from geometry and change fiducial cuts to be
>  at least corresponding to the size of the volume.
>- The MRS swimming does not check any y-range (apart from D2) and the tofw slat. (not changed).
>- there is a problem with 60 deg run-5 setting for MRS (found by coincidence)- kris is investigating.
>
>Note; You must also update brat since a new method has been added to BrDetectorVolume. (IsInsideX,..)
>         2.30.4
>
>
>Flemming Videbaek
>Physics Department 
>Brrokhaven National Laboratory
>
>phone: 631-344-4106
>fax:        631-344-1334
>e-mail: videbaek @ bnl.gov
>
>_______________________________________________
>Brahms-dev-l mailing list
>Brahms-dev-l@lists.bnl.gov
>http://lists.bnl.gov/mailman/listinfo/brahms-dev-l
>  
>

_______________________________________________
Brahms-dev-l mailing list
Brahms-dev-l@lists.bnl.gov
http://lists.bnl.gov/mailman/listinfo/brahms-dev-l
Received on Fri Nov 4 17:34:58 2005

This archive was generated by hypermail 2.1.8 : Fri Nov 04 2005 - 17:35:06 EST