The analyze app has ben updated with modification to the acceptance code. The main point was to introduce new maps for xf-pt . It is quite similar to the pVsTheta maps already there. During implementing this several problems were identified. - The code did not run due to typo's in newly added options for fiducial cuts. (fixed) - The inputoptions for fidicuals cuts are set to -99 and 99 in most cases. This in fact means the code does not check that tracks are inside the physical volumens at all. Corrected to get the volume size from geometry and change fiducial cuts to be at least corresponding to the size of the volume. - The MRS swimming does not check any y-range (apart from D2) and the tofw slat. (not changed). - there is a problem with 60 deg run-5 setting for MRS (found by coincidence)- kris is investigating. Note; You must also update brat since a new method has been added to BrDetectorVolume. (IsInsideX,..) 2.30.4 Flemming Videbaek Physics Department Brrokhaven National Laboratory phone: 631-344-4106 fax: 631-344-1334 e-mail: videbaek @ bnl.gov _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Fri Nov 4 14:24:42 2005
This archive was generated by hypermail 2.1.8 : Fri Nov 04 2005 - 14:24:55 EST