Hello, I have some little improvement on that: if you click on the plot, you get some ascii display of the parameter values in the form of a table. i.e. #================================= # Calibration parameters # Detector : TPM2 # Parameter : driftVelocity # Run range : [11200, 11500] #================================= Run Value 11201 0.00160043 11203 0.00160043 11204 0.00160043 11205 0.00160043 11206 0.00160043 11207 0.00160043 11209 0.00160043 11210 0.00160043 11211 0.00160043 11212 0.00160043 11213 0.00160043 11214 0.00160043 11218 0.00163372 11219 0.00163372 etc... That's very useful to track the very bad calibrations :) Now Truls, please update the TPM2 vdrift!!! Djam -- Djamel Ouerdane ------------------------------------------o | Niels Bohr Institute | Home: | | Blegdamsvej 17, DK-2100 Ø | Jagtvej 141 2D, | | Fax: +45 35 32 50 16 | DK-2200 Copenhagen N | | Tel: +45 35 32 52 69 | +45 35 86 19 74 | | http://www.nbi.dk/~ouerdane | | ouerdane@nbi.dk | o---------------------------------------------------------o _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Fri May 28 05:06:26 2004