Hello, I've succeded in fetching the calibration parameter values from the CGI script. I updated the link http://pii3.brahms.bnl.gov/daq-cgi-bin/cgiCalibrationDB.perl Give it a try, quite fun :) Buuut: I know that some parameters of a given detector can have different number of entries, e.g. the number of pads is != from number of rows in a TPC :). In the table generated by clicking a run number, the pad status column will be huge compared to the instrumented row column. I just made sure that the tables contained the necessary amount of entries. If someone wants to deal with special cases like the TPCs or DCs, cool. I don't have time to fool around anymore with this perl script. I think it is quite useful now and makes the DB browsers in brahms_app somehow obsolete :) Enjoy, Djam PS: there's one exercise left, namely the generation of a plot showing the evolution of a parameter with time but I leave that for someone else :) -- Djamel Ouerdane ------------------------------------------o | Niels Bohr Institute | Home: | | Blegdamsvej 17, DK-2100 Ø | Jagtvej 141 2D, | | Fax: +45 35 32 50 16 | DK-2200 Copenhagen N | | Tel: +45 35 32 52 69 | +45 35 86 19 74 | | http://www.nbi.dk/~ouerdane | | ouerdane@nbi.dk | o---------------------------------------------------------o _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Mon Apr 26 07:54:30 2004
This archive was generated by hypermail 2.1.8 : Mon Apr 26 2004 - 07:54:50 EDT