Hi Flemming, I have absolutely no idea why this is done. Please change it. -Ian On 17/3-2004, at 19:43, flemming videbaek wrote: > Hi > I am reviewing and have worked for a while to improve the tpc local > tracking to deal better with dead pads. > As you have also seen we have some real problems with the T2 response > with the y-dependence. While trying > to summarize ppotential imporvement it comes across that the T2 is > claimed only to have 8 active rows evwn though it > has 10. > How come ? It turns out that burried inside the BrTpcCalModule there > are statements that after having loaded the > padstatus parameters from the database executes the following. > > if detector is T2 > setRowInactive(13) setRowInactive(14) > > Why is this done??? if someone has a good answer please respond. > In any case I will remove this. (by the way it also means that no > tpc-timing cal exists for this two rows, albeit the > padstatus is worked out. > > Flemming > > > > ---------------------------------------------------------------- > Flemming Videbaek > Physics Department > Brookhaven National Laboratory > > e-mail: videbaek@bnl.gov > phone: 631-344-4106 > _______________________________________________ > Brahms-dev-l mailing list > Brahms-dev-l@lists.bnl.gov > http://lists.bnl.gov/mailman/listinfo/brahms-dev-l _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Thu Mar 18 04:21:29 2004
This archive was generated by hypermail 2.1.8 : Thu Mar 18 2004 - 04:21:43 EST