Hi I am reviewing and have worked for a while to improve the tpc local tracking to deal better with dead pads. As you have also seen we have some real problems with the T2 response with the y-dependence. While trying to summarize ppotential imporvement it comes across that the T2 is claimed only to have 8 active rows evwn though it has 10. How come ? It turns out that burried inside the BrTpcCalModule there are statements that after having loaded the padstatus parameters from the database executes the following. if detector is T2 setRowInactive(13) setRowInactive(14) Why is this done??? if someone has a good answer please respond. In any case I will remove this. (by the way it also means that no tpc-timing cal exists for this two rows, albeit the padstatus is worked out. Flemming ---------------------------------------------------------------- Flemming Videbaek Physics Department Brookhaven National Laboratory e-mail: videbaek@bnl.gov phone: 631-344-4106 _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Wed Mar 17 13:38:06 2004
This archive was generated by hypermail 2.1.8 : Wed Mar 17 2004 - 13:38:24 EST