From: Claus O. E. Jorgensen (ekman@nbi.dk)
Date: Mon May 19 2003 - 09:04:35 EDT
Hi Ramiro, After a busy week I've looked at the fields again, and I think the parametrization in BRAT is not right on the data. > The value of By at high field deviates from a linear function of the > current because of saturation and hopefully that is well described by > the parametrisation in BRAT. The plots (www.nbi.dk/~ekman/fieldVsCurrent.gif) shows that the measured By and the parametrization in BRAT (solid lines) differs sligthly at the high fields. It's clear that a 2nd degree pol cannot reproduce the saturation effect that the Hall probes show, so the question is if we want to put the numbers in the DB (I can see that Kris started this project some time ago) or maybe we could just use a 3rd degree pol in BRAT? If there are no objections I would like to change the parametrization, and then we can always put the numbers in the DB later. I just want to be sure that the By values I got are the right ones. Could you please send me tables with the latest and greatest measurements? Cheers, Claus