Dear Hiro,
I have to write a hit definition for the ZDCs. It cannot
be the same as for other detectors since 1 neutron will causes
hundreds of e+e- pairs to cross the optical fibers. One method
would be only to define the energy per event in each module.
Flemming asked me to impliment the next level of detail, ie the
energy in each module per track. This is in principle possible
since GEANT calls a user routine after it has finished processing
each primary track. I can do this but not until I return to
Texas. Even their it will take me some time. However I will
get back to you about this.
Yorus Michael
Quoting Hironori Ito <hito@students.phsx.ukans.edu>:
> Hello. I have 2 questions about the GBRAHMS.
>
> 1. Can I get a hit information for ZDC in GBRAHMS? I was not able to
> get
> any hit information for ZDC. And, when I look at the eg_zdc.F file, it
> does not look like it has ZDC hit stored in each event. When I run the
> GBRAHMS, I set ZDC by "set_tree zdc asfo". If I am doing wrong, please
> someone let me know.
>
>
> Hiro
>
Michael Murray, Cyclotron TAMU, 979 845 1411 x 273, Fax 1899
This archive was generated by hypermail 2b29 : Tue Feb 06 2001 - 12:24:05 EST