Dear all,
According to what I wrote in my previous email about the tof calibration
package, I have committed it into brahms_app/do_app
It will contain the stuff I told you before but also some simple
root scripts containing fit functions. These scripts are loaded by some
calibration modules during the main program Calibrate (not in a root
session). It means that you can modify these functions without recompiling
the program.
You have also some examples of option files:
options.txt -> when you read data
foptions.txt -> when you use the histo file already created by Calibrate
coptions.txt -> when you want to commit into the DB from a parameter file
produces by Calibrate
The use of this package is very straightforward after a couple of tries.
I think that it could be adapted to other detector calibrations.
---------------------------------------------
Concerning brat, I added the calibration parameter class
BrCalibrationParamsTOF in the tof directory.
Also, I have changed the ClassDef version number in BrDigTof.h
and BrCalTof.h, updated LinkBratTofINC.h et BrTof_LinkDef.h.
Please report any bugs when using this package.
To be honest, most of the stuff has been tested with H1, and some with H2.
In principle it should work with TOFW but people working on it could tell
me that.
Ciao.
Djam
:o) ****************************************************** )o:
|ME : Djamel Ouerdane EMAIL : ouerdane@nbi.dk |
|OFFICE : Tb1 @ NBI PHONE : +45 353 252 69 (office) |
|INST : Niels Bohr Institute, |
| Blegdamsvej 17, 2100 København Ø, Danmark |
:oD ****************************************************** \o:
This archive was generated by hypermail 2b29 : Wed Dec 13 2000 - 23:08:28 EST