TPC digitization.

From: videbaek (videbaek@sgs1.hirg.bnl.gov)
Date: Sat Sep 09 2000 - 13:23:52 EDT

  • Next message: Bjorn H Samset: "Adding things under CVS"

    Djamel, Peter
    I reviewed the digitization code, and found the problem - not in the dig. code itself but rather in the
    DetectorParamsTPC in DriftToTime routine used by digitization. Peter had found the problem
    introduced in the recent update in TimeToIntrinsic (used in tracking), but I did not realize then it would be
    wise also to check the other conversion methods for similar problems (from my coding). 
    The version is checked into CVS. I checked just counting TPCSequneces from a digitization
    of single pion tracks and see about a factor of two more seq. than before. I do NOT have a handy
    test code (any longer) that compares geant tracks with recosstructed tracks which can ensure the intregity.
    Please check it out now and report if it seems ok.
    
    
    ------------------------------
    Flemming Videbaek
    Physics Department
    Brookhaven National Laboratory
    tlf: 631-344-4106
    fax: 631-344-1334 
    videbaek@bnl.gov
     
    