    On Fri, 5 May 2000, Kris Hagel wrote:
    
    > Hello,
    > We have done a lot of work in the last few days
    > regarding the online monitor for BRAHMS.  This
    > Message details some of the enhancements that were  
    > made.
    >  
    > 5. Alv implemented a title header in pictures in the
    >    monitor.  This labels the pictures and gives the
    >    time they were generated.
    
      You can also get the run and event numbers used if you add the line
        BrDetectorMonitor::Event(InputTable);
    somewhere in the Event method of your detector monitor.
    
      This will put the run and event numbers of the first and last event that
    was filled into the histogram(s). The run and event numbers are reset when
    the "Clear Arrays" button is pressed.
    