¥Optimize slew parameters for each scintillator:
¥Need to determine the TOF vs E curve for
each PMT.
¥This will require 100 - 200 hits per
scintillator.
¥Require 12,000 - 24,000 hits per
wall.
¥Require 24,000 - 48,000 TOF tracks.
¥
¥Track assumptions:
¥There are 50 curved tracks per 1000
events.
¥A small fraction of these (1%?) will be
aimed at the TOF.
¥Required number of minimum bias events =
24,000 x 20 x 100 = 48,000,000.
¥