My “guide-lines” for this layout
Position and acceptance of the sensors are not changed
A 1 mm clearance between sensors is always maintained
The hybrid is as similar as possible to the Octagon hybrid and can be done on PCB’s
The modules fit into the existing mechanics
The cable length is minimized
The readout can be done in groups of 2, 4, or 8 modules in a string.