Shift Check List for TOF- No Access/ No Beam

Check

Measurement

Action

Comment

High Voltage To TOF

 

 

 

HV On?

Yes c No c

If OFF, note in the logbook.

 

TOF tubes enabled (Slots 0-9)?

Yes c No c

Note disabled channels and why in logbook.

 

TOF Discriminators

 

 

 

Is X and Q valid?

Yes c No c

If no, read out crates and recheck. If still invalid, note in logbook.

 

Channels unmasked for crate #3 and #4?

Yes c No c

Note masked channels in logbook.

 

Diagnostic Run Mode Checks

     

Is TOF self-trigger enable and routed to trigger electronics?

Yes c No c

If yes, note in logbook.

 

Is LED HV Off?

Yes c No c

If No and there is no LED run commencing, turn Off.

 

Is Time Calibrator Off?

Yes c No c

If No and there is no calibration run commencing, turn off.

 

Date of last LED run

 

If greater than a week, perform an LED run.

 

Date of last Calibration run.

 

If greater than a month, perform a Calibration run.

 

Date of last Cosmic run.

 

If greater than a week, perform a Cosmic run.