Go to the RHIC X-term computer and find the 'Magnets' window.
| Instructions | Measurements | Actions To Take | Comments |
| Look at 'A Mode' on fourth 'wfg.phobosMagnet.ps' line | Mode is
A c B c |
If Mode is set to 'B', change it to 'A' by choosing 'A' from the drop-down menu and clicking on the middle button when the cell becomes red. |
Go to the Magnet Monitoring Program on the 'MAGMON' computer.
| Instructions | Measurements | Actions To Take | Comments |
| Is there a black arrow in window 'MobitorMagnet.vi'? | Black arrow?
Yes c No c |
If NO, click on the 'arrow' to start the VI. Double click on the 'Magnet Monitoring' icon on the desktop if there is no 'MobitorMagnet.vi' window. | |
| Look at 'Measured I' and 'Measured V'. Are the values fluctuating (around zero when the magnet is off)? | Values fluctuating?
Yes c No c |
If NO, exit 'LabView' and double click on the 'Magnet Monitoring' icon on the desktop. | |
| Look at 'StatusStringM' in the window, does the string say 'Off'? | Magnet is
On c Off c |
If the magnet is 'Off' you can ignore 'Fault' or 'Component Fault' messages. |