| Instructions | Measurements | Comments | Actions To Take |
| On 'DAQ X-Term' locate 'runcontrol' window | |||
| enter following command: rc_status() |
|||
| Check the 'Run state' | 'stopped' | DAQ was stopped | Checklist is finished successfully. |
| 'started' | Continue checklist | ||
| wait ~10 sec and repeat the command again: rc_status() |
|||
| Check the difference dEv between current and previous number of events | dEv>0 | DAQ is running | Checklist is finished successfully. |
| dEv=0 | DAQ was stopped due to some failure or there are no input triggers | Continue checklist | |
| Check for running messages in 'phatdaq' window | no messages | no input triggers | Checklist is finished successfully. But if you are sure that there should be triggers then call expert |
| running messages |
Something happened | Call expert |