Hi I found 2 bugs in BrDetectorParametersTPC : * The slope parameters were not initialised to 0 resulting in a small jump for one row in TPM2. * When read from file only 2 not 3 were read. The format should now be fTimeCorrection: row offset slope (slope = 0 when no slope) * I also noticed that in the new data row 9, 10 are not instrumented in TPM2 (I guess the cards have been moved to cover all of the TOFW) and so I set 9 and 10 to kFALSE in the class and in the DetectorParameters.txt file. This affects the tracking quite alot since it else count the 2 rows as misses allowing only 1 other row to be missed. * Finally I commented the row-time correction for T1 and T2 out, but kept it for TPM2 since there it was obviously needed. We soon have to remake the corrections for the new fixed Tpcs to see what is left. NB! The last 2 things affects people analyzing old runs !!!! They will have to include the old changes in a special parameter file and use that file. Afraid that some people might dislike some of the stuff I did I tagged brat (2.0.16). Please write me if you see strange missing tracks or misplaced hits with the tpc3d monitor (RunNo and EventNo and detector). (I know that the hits are misplaced for T2 in the z direction, but I think this is because of the hardcoded padlength in the monitor code). Cheers Peter -- :-) --------------------------------- )-: |Peter H L Christiansen aka PAN @ NBI | |EMAIL : pchristi@nbi.dk | |OFFICE : Tb1 @ NBI | |PHONE : 353 25269 | |SNAIL : Hans Tavsensgade 35, 4th | |PHONE : 35 349336 | :-D --------------------------------- \-: