Shifter leader was rk Shifters were Of course the previous report was also from 0000-0800 shift. Sorry for sending this twice... 1. We had beam all night but for about 2 hours - the dump was unexpected and caused by failure of our D2 - 24V power supply failure and problems with waveform generator - will be fixed today. 2. The following runs were recorded (FS at 2.3deg full field B, MRS at 90deg full field B): 14733-35,14737-45 (14740-14742 non-existent because of IOserver and RunServer problems). 3. Once again - big problems with D2 (D1 is also not doing fine, as reported by previous shifter - HI) - few modules will be changed today. Probably D2 trips caused also DC to trip - had to restart 1458B mainframe. _______________________________________________ Brahms-l mailing list Brahms-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-lReceived on Wed May 18 08:20:48 2005
This archive was generated by hypermail 2.1.8 : Wed May 18 2005 - 08:20:52 EDT