Shifter leader was SB Shifters were 1. Beam from previous shift was lost at the beginning of the night shift. RHIC had power supply problem until about 4:15 am. New store since then and running physics. Beam to be dumped at 9:20 am. 2. Pedestal runs: 13213, 13214; Setting FS@4 deg. @A3450 MRS@40 deg. @A2255 RunNo Trig2 Trig3 13215 - 251k - 103k 13216 - 202k - 158k 13217 - 221k - 207k 3. Checking high voltages, I found that F1-xu and F1-yv on T3 had tripped may be due to the sudden beam loss at begining of shift. Trip was cleared by turning them off and back on again. All cathods and Field1 on T5 had also tripped. Trip was cleared the same way and all is well. _______________________________________________ Brahms-l mailing list Brahms-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-lReceived on Thu Feb 17 07:54:48 2005
This archive was generated by hypermail 2.1.8 : Thu Feb 17 2005 - 07:54:56 EST