From: Apache (apache@pii3.brahms.bnl.gov)
Date: Sat Feb 01 2003 - 16:24:06 EST
------------------------------------------------------------ Date: Sat Feb 1 16:24:06 2003, Shift: 08:00-16:00 Supervisor: KH, with: ZY Log book#13 pages 136 - 137 Shift Summary: ------------------------------------------------------------ 1. Beam dumped at 10:30. No beam comes after that. 2. FS magnets changed to 1/8A (D1=427A). We now have a total of 152+17+13+10K=192K events total at 1/8A 3. MRS continued at 6A (D5=1050A). There is now a total of about 200K events at that setting 2. Data runs: 7721, 7722, 7723, 7724 T1 anode tripped in run 7721 and 7722 7726 is TPC pedestal run, 7727 non-TPC pedestal run 3. T1 anode tripped three times. We decided to lower the anode voltage to 1200V. In addition we set the trip current of T1 anode to 20uA as well as a peak trip limit of 50uA. 4. The version of SummaryPlots in operator account was not in sync with brntuple in there. So I updated brntuple then found that it would not link. Traced that to BrNtupleScaler not being in makefile, so I fixed that and now that seems to work. 5. Badtrip was not alerting us when T1 anode tripped, so Flemming fixed badtrip to read the proper number of from the config file and we also set the config file to look at the proper elements to know when to beep. We have not been able to test it with beam, but at least it beeped when voltage was turned off. ------------------------------------------------------------
This archive was generated by hypermail 2.1.5 : Sat Feb 01 2003 - 16:28:44 EST