------------------------------------------------------------ Date: Sat Dec 22 16:00:58 2001, Shift: 08:00-16:00 Supervisor: fv, with: fv Log book#11 pages 74 - 78 Shift Summary: ------------------------------------------------------------ 1 .Machine mainly in study mode - so much for physics run. 2. misc clean up of trigger and checkout. see details below 3. The pii4 has no virtual desktop (icons disapeear) scaledoan problesm for some trigfger channels - moved around. Plan: move BFS to align with FFS at 8 deg. collect data with Inel+ MRS and FS spec trigger at 1/8 FS field and 2Kg MRS Aim ~ 50k FS trigger, and similar 2* for MRS. before checking response. 8.40: Rhic polarization measurements. (Beam should be dumped afterwards). Trigger 1 ( Beam-Beam Left+Right all tubes >=1 hit in coinc) Trigger (Inel ) 9.00 When they do polarization measurements the inel background rate goes up by ~30% (3000/sec -> 4200/sec).MCR calls ahead of this, Beware that data runs MUST be stopped when Pol measurements are done. It takes ABout 1/2 hour and is done and start and beginning of each store. It is not necessary to turn off/down the anode voltages. 9.10 The printer demon. Seem not to like certain monitor output printerfiles and dies. I had to restart lpd. This can only be done by super-user. Is the possible reason that the .ps files supermon produces all have the same files?? In addition it gives an error (Betty notice) ./lpd start Starting lpd: Warning - cannot stat 'if' filter '/var/spool/lpd/psct510a/filter' - No such file or directoryWarning - cannot stat 'if' filter '/var/spool/lpd/pscp510a/filter' - No such file or directory Another comp note: On pii4 the virtual desktop bar has disapeared such the iconizes a window mean you cannot get at it again !!! Does anyone know how to fix this ? 9.56 Ted does not display t1, T2 tracks any longer even when tpc3d shows very reasonable clusters, and tpm1 tpm2 does. My guess is it has to do with hidden options /requieremnents (like beam beam,) in the tracking package. This after After spending (wasting) some time attempting to see why Ted did not display any T1,T2 information though triggering + anodes + etc looks good ~10.00 Beam was finally dumped. The polarization measurements took a hole hour not so good. 11.20 Machines studies and access at 2.00 (Phenix planned). Beam possibly at 4.00 . So this is physics running ?? - studies as well as low intensities? 11.35 Note Hiro made a new ntuple macro for the pp run it is called SummaryPlotsPP.C; runs as usual. 11.45 Modified SummaryPlotsPP.C to only show Tpc sequences for trigger 3 and 6. 12.00 By looking at the ntuple plots from last night it is clear the TPC anode were in standby, not on . This explains the lack of tracks correlated to the trigger 3/6. 13.00 Tracking down the 'scale-down problem for trigger 2/4 for the inel counter. Found that the inputwidth to the enable gate (delivered by the top 821 ch #2) was narrower than for the other inputs. This though turns out not to be the problem. It must have to do with the nim/ecl-scaledown and back to Nim. Setting Inel to channel 5 inttead for long term stability test. Thus from run 6113 and on. Trigger 1 -- Beam/Beam L.R Trigger 3 -- MRS-F.Mrs.Back and Inel Trigger 5 -- Inel Trigger 6 -- FS D1Tr and H1 13.15 The first majority output of the first Malu (left) has appeared intermittent for some time. Terminated the output and diasychained the small & Big tube to same linear amp. For the Au-Au the two were independently to seperate fan in/out. 14:14 Clean up of trigger cable delays for MRS and FS trigger. All times kept. Still needs fine adjustments. 15:15 1 hours controlled access. -- Beam hours: 8-9 when announchment of pol measurements were made. ------------------------------------------------------------
This archive was generated by hypermail 2b30 : Sat Dec 22 2001 - 16:01:44 EST