As some of you know there has been considerable problem in having the 62 gev cucu properly calibrated for tfw2. After much digging and discussion Truls found a coding mistake in the tof slewing calibration software for the case where the adc'gap' is taken into account. The corrected code is now in cvs. It may affect other analysis depending how the slewing software has been run. I rechecked the case for pp run-5 and run-6. The software was run w/o taken into account the 'gap'. This is per say a mistake, but has apparently very little effect on the final result (much data is below the GAP) the overall time resolution for run 14071-14073 changed from ~ 125 psec to 119 psec integrated over all slats. I think this can be safely ignored, but should be kept in mind for other analysis. regards Flemming -------------------------------------------- Flemming Videbaek Physics Department Bldg 510-D Brookhaven National Laboratory Upton, NY11973 phone: 631-344-4106 cell: 631-681-1596 fax: 631-344-1334 e-mail: videbaek @ bnl gov _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l_at_lists.bnl.gov https://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Wed Jul 11 2007 - 07:31:07 EDT
This archive was generated by hypermail 2.2.0 : Wed Jul 11 2007 - 07:31:36 EDT