[Brahms-dev-l] tfw2 slewing..

From: Flemming Videbaek <videbaek_at_bnl.gov>
Date: Wed, 11 Jul 2007 07:30:20 -0400
As some of you know there has been considerable problem in having the 62 gev cucu properly calibrated for tfw2.
After much digging and discussion Truls found a coding mistake in the tof slewing calibration software for the case where the  adc'gap'
is taken into account.

The corrected code is now in cvs.

It may affect other analysis depending how the slewing software has been run. I rechecked the case for pp run-5 and run-6.
The software was run w/o taken into account the 'gap'. This is per say a  mistake, but has apparently very little effect on
the final result (much data is below the GAP) the overall time resolution for run 14071-14073 changed from ~ 125 psec to 119 psec integrated over all
slats. I think this can be safely ignored, but should be kept in mind for other analysis. 

regards
    Flemming





--------------------------------------------
Flemming Videbaek
Physics Department 
Bldg 510-D
Brookhaven National Laboratory
Upton, NY11973

phone: 631-344-4106
cell:       631-681-1596
fax:        631-344-1334
e-mail: videbaek @ bnl gov


_______________________________________________
Brahms-dev-l mailing list
Brahms-dev-l_at_lists.bnl.gov
https://lists.bnl.gov/mailman/listinfo/brahms-dev-l
Received on Wed Jul 11 2007 - 07:31:07 EDT

This archive was generated by hypermail 2.2.0 : Wed Jul 11 2007 - 07:31:36 EDT