Re: [Brahms-dev-l] [Brahms-l] RICH Calibration in CuCu

From: Flemming Videbaek <videbaek_at_bnl.gov>
Date: Sat, 3 Feb 2007 15:20:05 -0500
Hi
I just looked at the elog for 12315; there it is already noted in the elog that settings and CDEV do not correspond. SO this is no 
surprise, if the DB still have the wrong field values.
Morale:
check the elog. It may in fact contain valuable information

flemming

--------------------------------------------
Flemming Videbaek
Physics Department
Bldg 510-D
Brookhaven National Laboratory
Upton, NY11973

phone: 631-344-4106
cell:       631-681-1596
fax:        631-344-1334
e-mail: videbaek @ bnl gov
----- Original Message ----- 
From: "Flemming Videbaek" <videbaek_at_bnl.gov>
To: "Bekele, Selemon" <bekeleku_at_ku.edu>; "devlist" <brahms-dev-l_at_lists.bnl.gov>
Sent: Saturday, February 03, 2007 3:13 PM
Subject: Re: [Brahms-dev-l] [Brahms-l] RICH Calibration in CuCu


> Hi Selemom,
>
> This indeed look peculiar; I can see by looking at individual files that the 12434 is the problem.
> Since the radius is determined from the hit patterns on the RICH, and momentum in fact can be determined from the radius when not
> saturated, it indicates that the Field was not the proper value
> (but lower) for these runs. The DB as well as elog printout does not indicate any particular problem.
> The gtr printout has same field for surrounding runs.
> I could not access opus today to look for the CDEV readout of magnet during the runs.
> Maybe Ramiro or someone else could lookup the Hallprobe keithley settings for these runs.
> I did not look at the higher runs.
> Unless we find the problem, I suggest the runs is omitted from the list of good runs!
>
> flemming
>
>
>
> --------------------------------------------
> Flemming Videbaek
> Physics Department
> Bldg 510-D
> Brookhaven National Laboratory
> Upton, NY11973
>
> phone: 631-344-4106
> cell:       631-681-1596
> fax:        631-344-1334
> e-mail: videbaek @ bnl gov
> ----- Original Message ----- 
> From: "Bekele, Selemon" <bekeleku_at_ku.edu>
> To: <brahms-l_at_lists.bnl.gov>
> Sent: Saturday, February 03, 2007 1:46 PM
> Subject: [Brahms-l] RICH Calibration in CuCu
>
>
>>
>> Hi,
>>
>>   please have a look at the rich calibration
>> plots for CuCu_at_200 GeV at
>>
>>    http://www4.rcf.bnl.gov/~tigist/RichCalibration/cucu/200/
>>
>> The band bewtween the pions(red) and the kaons (blue) in RadiusVsP_4A1219_Runs12427_12434.gif
>> correponds to the run
>>
>> "/brahms/data03//data/run05/cucu/200/r12434/dst/dst012434v1p3.root" //this file from 4A1219
>>
>> The band bewtween the pions and the kaons in "RadiusVsP_8B1219_Runs12315_12497.gif"
>> correponds to the run
>>
>> "/brahms/data03//data/run05/cucu/200/r12315/dst/dst012315v1p3.root" //this file from 8B1219
>>
>> Need to look at what the cause is.
>>
>> Selemon,
>> _______________________________________________
>> Brahms-l mailing list
>> Brahms-l_at_lists.bnl.gov
>> http://lists.bnl.gov/mailman/listinfo/brahms-l
>>
>
> _______________________________________________
> Brahms-dev-l mailing list
> Brahms-dev-l_at_lists.bnl.gov
> http://lists.bnl.gov/mailman/listinfo/brahms-dev-l
> 

_______________________________________________
Brahms-dev-l mailing list
Brahms-dev-l_at_lists.bnl.gov
http://lists.bnl.gov/mailman/listinfo/brahms-dev-l
Received on Sat Feb 03 2007 - 15:21:20 EST

This archive was generated by hypermail 2.2.0 : Sat Feb 03 2007 - 15:21:35 EST