This depends on your run range. The easiest way to see how often the dst will have the corrected index, is to look in the calibration webpage. Ask for rich and the run range. When a gasparameters is there the gtr/dst ought to be with corrected index. -------------------------------------------- Flemming Videbaek Physics Department Bldg 510-D Brookhaven National Laboratory Upton, NY11973 phone: 631-344-4106 fax: 631-344-1334 e-mail: videbaek @ bnl.gov ----- Original Message ----- From: "Stephen Sanders" <ssanders@ku.edu> To: "Brahms Dev" <brahms-dev-l@lists.bnl.gov> Sent: Tuesday, February 14, 2006 10:58 AM Subject: [Brahms-dev-l] RICH Index of Refraction question(s) > Hi: Are the RICH radii in the latest dst's corrected for the changing > index of refraction? If so, what is the reference IOF? If not, are > people > changing their PID limits on a run-by-run basis? > Any guidance greatly appreciated! Thanks. ..steve > _______________________________________________ > Brahms-dev-l mailing list > Brahms-dev-l@lists.bnl.gov > http://lists.bnl.gov/mailman/listinfo/brahms-dev-l > _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Tue Feb 14 12:26:05 2006