Hello devl's, Because I'd like to make new DSTs for the 63 GeV runs, I refined the TOF calibration. I could commit some new time offsets without any problems last week but now, when I want to commit ADC gap stuff, the script runs smoothly but something weird occurs then : the comment string I want to attach to the values I am committing is obviously greater than 16 characters but still, I get a warning that it is shorter than that. That's a 1st hint that something does not propagate correctly. When I then check the DB values either from the DAQ website or from one of the brat based browser, I get the old values (which are plain wrong by the way). This confirms that somewhere in the commit chain, the input is not propagated. As I said, it works fine for other calibration parameters like time offsets. Any clue ? Djam _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Mon Nov 8 06:11:07 2004