Hi Zhongbao; I finished the efficiency calculation for p+p. You can find the results in file ~ufstasze/effic/EfficDataInRun3.root, in the form of 1dim histograms, 3 histograms for each settings and each detector. _1 (in the histogram name) refer to x (local detector position) dependence _2 - momentum dependence _3 - x-slope dependence. I believe that any momentum dependence is related to x dependence, so I would suggest to apply only x dependence (parametrized it or directly use the histogram). If bin content is 0 this means that the efficiency has not been calculated for the selected bin. In this case use value from the nearest bin with non-zero value. Cheers Pawel. _______________________________________________ Brahms-dev-l mailing list Brahms-dev-l@lists.bnl.gov http://lists.bnl.gov/mailman/listinfo/brahms-dev-lReceived on Fri Dec 19 11:39:21 2003