From: Hironori Ito (hito@rcf.rhic.bnl.gov)
Date: Tue Apr 01 2003 - 18:44:39 EST
Hello. I finished the slewing of inelastic counters. The result is quite good. Without slewing, the resolution is typically 10cm. For particular run that I was looking at (run 8404 global run), it was 14cm. This is shown in http://pii3.brahms.bnl.gov/~hito/Inel/inelvertex_resolution_noslew1.gif With a carfull slewing, it is now less than 5cm for the same run, this is shown in http://pii3.brahms.bnl.gov/~hito/Inel/inelvertex_resolution1.gif Hiro (Note: My code is not in brat yet.)