From: Flemming Videbaek (videbaek@sgs1.hirg.bnl.gov)
Date: Tue Oct 29 2002 - 12:53:04 EST
In the course of debugging the addition of detectors to brag a problem was discovered with gbr2c.f that means that the 'local'coordinates for hits in MULT was not local but global so far. This is now fixed. At the same time the beam-beam counters have an added option so one can specify to have a pb-converter in front of each tube. (to use 'set_param bb pb 0.5 ' to speficy a 5mm circular rad in front of each tubes. By default it is off. The brag version was tagged BRAG-1-1-24 ------------------------------------------------------ Flemming Videbaek Physics Department Brookhaven National Laboratory tlf: 631-344-4106 fax 631-344-1334 e-mail: videbaek@bnl.gov