BRAT-2-1-40, dNdEta calculations added

From: Stephen J. Sanders (ssanders@ku.edu)
Date: Sat Nov 24 2001 - 11:12:50 EST

  • Next message: Christian Holm Christensen: "Re: BRAT-2-1-40, dNdEta calculations added"

    Hi,
    I've modified a number of si and tile classes (BrSiCalibration, 
    BrTileCalibration,
    BrMultRdo, BrMultRdoModule) to add event-by-event calculations of dNdEta 
    for each
    si and tile ring.  I also added a calculation of the HIJING weighted 
    average
    pseudorapdity for each ring.  
    
    We were already calculating the number of "primary" particles hitting each
    detector element based on HIJING simulations that relate these particle 
    multiplicites
    to the observed energy deposited in each si and tile element. I have now
    added calibrations that relate the particle multiplicites to a dNdEta 
    value based
    on the measured vertex position. To obtain the calibrations I position a 
    simulated
    vertex between -46 cm and +46 cm, in 2 cm steps, and at each position did
    a "throw" of HIJING 0-2 fm primary events (no CASCADE...).  Each 
    particle was
    checked to see if it hit on the si or tile detectors.  I also kept track 
    of the total
    number of particles within the pseudorapity range covered by each 
    detector. This
    procedure allows for a simple geometric efficiency calculation.
    
    Although the dNdEta and <eta> values are calculated internally for each 
    si and tile detector
    elements, I am only placing the average value obtained for each si and 
    tile "ring" in the
    BrMultRdo data structure. (42 values for the Si, 8 for the tiles).
    
    I have retagged brat as 2.1.40 and I have bumped the  BrMultRdo classdef 
    to 2.
    
    Regards, Steve
    